According to imperfection of permeability test for anti-seepage wall in dyke construction,three-segment algorithm for seepage calculation of the homogeneous earth dike on impervious foundation is referenced,and five-segment algorithm of permeability coefficient of anti-seepage wall is presented.And then the algorithm is verified by numerical simulation of water injection test.The result shows that when the difference between permeability of soil mass and anti-seepage wall is in the range of 200-1 000 times,inspection results is more accurate;when the permeability difference is less than 200 times,with increase of numbers of downstream inspection hole,the error will be eliminated;when the permeability difference is larger than 1 000 times,the calculation error can not be eliminated but the results can be used for qualitative analysis.Therefore,the algorithm can be applied to the practical engineering by setting certain conditions.
[1]白永年.中国堤坝防渗加固新技术[M].北京:中国水利水电出版社,2002.
[2]何洪民.高压喷射灌浆技术在堤防截渗工程中的应用[J].黑龙江水利科技,2006,34(5):98-100.
[3]张生,董永全,李希宁,等.水泥土截渗墙技术在黄河堤防中的应用[J].人民黄河,2002(2):15-16.
[4]卢晓鹏.高压喷射灌浆技术在云南病险水库加固工程中的应用[J].水利水电科技进展,2012,32(5):82-85.
[5]李长顺,康家亮,梁大明.群孔压水试验在松山大坝防渗检测中的应用[J].东北水利水电,2011(9):28-29.
[6]于兰刚.鹤岗市五号水库大坝帷幕灌浆质量分析[J].水利科技与经济,2005,11(3):184-185.
[7]王明森,王洪恩,查振衡,等.高压喷射灌浆防渗加固技术[M].北京:中国水利水电出版社,2010.
[8]韦港,闫宇.关于注水试验不适合均质土坝坝体渗透性测试的讨论[J].水利水电科技进展,2009,29(4):18-20.
[9]水利部水利水电规划设计总院,长江勘测规划设计研究院,黑龙江省水利水电勘测设计研究院,等.堤防工程设计规范(GB50286-2013)[S].北京:中国计划出版社,2013.
Basic Information:
DOI:10.20040/j.cnki.1000-7709.2013.06.042
China Classification Code:TV223.42
Citation Information:
[1]JI Wei,TENG Hongmei,CHEN Yan,DU Bei,HOU Zhongyuan,ZHANG Lei,WANG Lili(Institute of Water Conservancy Works Design of Xuzhou,Xuzhou 221000,China).Five-segment Algorithm for Permeability Coefficient of Anti-seepage Wall in Homogeneous Earth Dike on Impervious Foundation[J].Water Resources and Power,2013,31(06):144-146+176.DOI:10.20040/j.cnki.1000-7709.2013.06.042.
2013-06-25
2013-06-25